ISO 286 TOLERANCES
H7 tolerance chart
ISO 286 values for the H7 and h7 tolerances. Enter a size to see the limits; a table for every size band follows below.
Dimension and tolerance
Standard
Feature type
Quick entry by tolerance notation
Examples: 20 h9 · 25 H7/g6
Verified table coverage: 0 < size ≤ 3150 mm; class-specific limits apply. Lists change with dimension. A selected class is not a delivery tolerance commitment.
TOLERANCE CALCULATION
Size limits
Diameter
H7- Minimum size
- 25 mm
- Maximum size
- 25.021 mm
- Lower deviation
- 0 µm (0 mm)
- Upper deviation
- +21 µm (+0.021 mm)
- Tolerance width
- 21 µm (0.021 mm)
Check a measured size
This check compares numerical size limits only; it does not assess measurement uncertainty or form tolerances.
The result shows size limits for the selected ISO class. Ovality, straightness, surface roughness and temperature effects are outside this calculation.
H7 tolerance chart
Values from ISO 286-2 for every size band up to 3150 mm, in micrometres (µm). Add the deviations to the nominal size; the calculator above gives the limits in millimetres.
H7 tolerance chartupper / lower deviation, µm · IT: tolerance width, µm
| Size (mm) | H7 hole | h7 shaft | IT7 |
|---|---|---|---|
| 0–3 | +10 / 0 | 0 / −10 | 10 |
| 3–6 | +12 / 0 | 0 / −12 | 12 |
| 6–10 | +15 / 0 | 0 / −15 | 15 |
| 10–18 | +18 / 0 | 0 / −18 | 18 |
| 18–30 | +21 / 0 | 0 / −21 | 21 |
| 30–50 | +25 / 0 | 0 / −25 | 25 |
| 50–80 | +30 / 0 | 0 / −30 | 30 |
| 80–120 | +35 / 0 | 0 / −35 | 35 |
| 120–180 | +40 / 0 | 0 / −40 | 40 |
| 180–250 | +46 / 0 | 0 / −46 | 46 |
| 250–315 | +52 / 0 | 0 / −52 | 52 |
| 315–400 | +57 / 0 | 0 / −57 | 57 |
| 400–500 | +63 / 0 | 0 / −63 | 63 |
| 500–630 | +70 / 0 | 0 / −70 | 70 |
| 630–800 | +80 / 0 | 0 / −80 | 80 |
| 800–1000 | +90 / 0 | 0 / −90 | 90 |
| 1000–1250 | +105 / 0 | 0 / −105 | 105 |
| 1250–1600 | +125 / 0 | 0 / −125 | 125 |
| 1600–2000 | +150 / 0 | 0 / −150 | 150 |
| 2000–2500 | +175 / 0 | 0 / −175 | 175 |
| 2500–3150 | +210 / 0 | 0 / −210 | 210 |
Worked examples
- Ø10 H7 hole: in the 6–10 mm band H7 is +15 / 0 µm, so the size must lie between 10.000 and 10.015 mm.
- Ø10 h7 shaft: in the 6–10 mm band h7 is 0 / −15 µm, so the size must lie between 9.985 and 10.000 mm.
- Ø25 H7 hole: in the 18–30 mm band H7 is +21 / 0 µm, so the size must lie between 25.000 and 25.021 mm.
- Ø25 h7 shaft: in the 18–30 mm band h7 is 0 / −21 µm, so the size must lie between 24.979 and 25.000 mm.
What does H7 mean?
In an ISO 286 code the letter gives the position of the tolerance zone relative to the nominal size and the number its width (grade IT7). Capital letters are for holes, lower case for shafts.
In H7 the lower deviation is zero: the hole can never be smaller than the nominal size, only larger.
In h7 the upper deviation is zero: the shaft can never exceed the nominal size, only be smaller.
IT7 is usually reached by reaming, precision turning or grinding.
Where is H7 used?
H7 is the most widely used hole tolerance in mechanical engineering: the standard class for reamed or precision-machined holes, paired with g6, h6, k6, n6 or p6 shafts. h7 is used on precision-turned or ground shafts.
How to read the H7 tolerance chart
First find the row containing the nominal size: “10–18” covers sizes above 10 mm up to and including 18 mm. Add the upper and lower deviations of that row, in micrometres, to the nominal size; 1000 µm = 1 mm.
The tolerance width is the difference between the upper and lower deviation and equals IT7. Classes ending in the same number (for example H7, h7, js7) share this width; the letter only moves the zone.
Frequently asked questions
What is the H7 tolerance value?
H7: 10–18 mm: +18 / 0 µm; 18–30 mm: +21 / 0 µm; 30–50 mm: +25 / 0 µm. h7: 10–18 mm: 0 / −18 µm; 18–30 mm: 0 / −21 µm; 30–50 mm: 0 / −25 µm. The value grows with size; other bands are in the table.
What are the limits of Ø20 H7?
H7: 20.000 – 20.021 mm (+21 / 0 µm); h7: 19.979 – 20.000 mm (0 / −21 µm).
What is the difference between H7 and h7?
Capitals are hole tolerances, lower case shaft tolerances. At Ø25 mm H7 is +21 / 0 µm and h7 0 / −21 µm: the same width (IT7) in a different position.
Where is H7 used?
H7 is the most widely used hole tolerance in mechanical engineering: the standard class for reamed or precision-machined holes, paired with g6, h6, k6, n6 or p6 shafts. h7 is used on precision-turned or ground shafts.
What does IT7 mean?
IT7 is the ISO 286 tolerance grade and sets the width of the tolerance; it grows with size. At Ø25 mm IT7 = 21 µm. IT7 is usually reached by reaming, precision turning or grinding.
How do I calculate a H7 tolerance?
Find the band containing the nominal size and add the upper / lower deviation (µm) to it. Example: Ø20 H7: 20 +21 µm = 20.021 mm and 20 0 µm = 20.000 mm. The calculator does this for you.