PRECISION IN MATERIAL. CLARITY IN SUPPLY.

ISO 286 TOLERANCES

JS7 tolerance chart

ISO 286 values for the JS7 and js7 tolerances. Enter a size to see the limits; a table for every size band follows below.

Dimension and tolerance

Standard

Feature type

Tolerance class
ISO js7
Quick entry by tolerance notation

Examples: 20 h9 · 25 H7/g6

Verified table coverage: 0 < size ≤ 3150 mm; class-specific limits apply. Lists change with dimension. A selected class is not a delivery tolerance commitment.

TOLERANCE CALCULATION

Size limits

25 js7 js7: 24.9895 – 25.0105 mm (-10.5 / +10.5 µm)

Diameter

js7
Minimum size
24.9895 mm
Maximum size
25.0105 mm
Lower deviation
-10.5 µm (-0.0105 mm)
Upper deviation
+10.5 µm (+0.0105 mm)
Tolerance width
21 µm (0.021 mm)
Check a measured size

This check compares numerical size limits only; it does not assess measurement uncertainty or form tolerances.

Tolerance zone µm
Nominal · 0js7-10.510.5

Calculate weight from nominal dimensions

The result shows size limits for the selected ISO class. Ovality, straightness, surface roughness and temperature effects are outside this calculation.

JS7 tolerance chart

Values from ISO 286-2 for every size band up to 3150 mm, in micrometres (µm). Add the deviations to the nominal size; the calculator above gives the limits in millimetres.

JS7 tolerance chartupper / lower deviation, µm · IT: tolerance width, µm
Size (mm)JS7 holejs7 shaftIT7
0–3+5 / −5+5 / −510
3–6+6 / −6+6 / −612
6–10+7.5 / −7.5+7.5 / −7.515
10–18+9 / −9+9 / −918
18–30+10.5 / −10.5+10.5 / −10.521
30–50+12.5 / −12.5+12.5 / −12.525
50–80+15 / −15+15 / −1530
80–120+17.5 / −17.5+17.5 / −17.535
120–180+20 / −20+20 / −2040
180–250+23 / −23+23 / −2346
250–315+26 / −26+26 / −2652
315–400+28.5 / −28.5+28.5 / −28.557
400–500+31.5 / −31.5+31.5 / −31.563
500–630+35 / −35+35 / −3570
630–800+40 / −40+40 / −4080
800–1000+45 / −45+45 / −4590
1000–1250+52.5 / −52.5+52.5 / −52.5105
1250–1600+62.5 / −62.5+62.5 / −62.5125
1600–2000+75 / −75+75 / −75150
2000–2500+87.5 / −87.5+87.5 / −87.5175
2500–3150+105 / −105+105 / −105210

Worked examples

  1. Ø10 JS7 hole: in the 6–10 mm band JS7 is +7.5 / −7.5 µm, so the size must lie between 9.993 and 10.008 mm.
  2. Ø10 js7 shaft: in the 6–10 mm band js7 is +7.5 / −7.5 µm, so the size must lie between 9.993 and 10.008 mm.
  3. Ø25 JS7 hole: in the 18–30 mm band JS7 is +10.5 / −10.5 µm, so the size must lie between 24.990 and 25.011 mm.
  4. Ø25 js7 shaft: in the 18–30 mm band js7 is +10.5 / −10.5 µm, so the size must lie between 24.990 and 25.011 mm.

What does JS7 mean?

In an ISO 286 code the letter gives the position of the tolerance zone relative to the nominal size and the number its width (grade IT7). Capital letters are for holes, lower case for shafts.

JS7 is symmetric: the upper and lower deviations are equal on either side of the nominal size.

js7 is symmetric: the upper and lower deviations are equal on either side of the nominal size.

IT7 is usually reached by reaming, precision turning or grinding.

Where is JS7 used?

JS7 and js7 are symmetric tolerances: the deviation is split evenly on both sides of the nominal size (± IT7 / 2). Used for location dimensions that should sit centrally and in transition fits.

How to read the JS7 tolerance chart

First find the row containing the nominal size: “10–18” covers sizes above 10 mm up to and including 18 mm. Add the upper and lower deviations of that row, in micrometres, to the nominal size; 1000 µm = 1 mm.

The tolerance width is the difference between the upper and lower deviation and equals IT7. Classes ending in the same number (for example H7, h7, js7) share this width; the letter only moves the zone.

Frequently asked questions

What is the JS7 tolerance value?

JS7: 10–18 mm: +9 / −9 µm; 18–30 mm: +10.5 / −10.5 µm; 30–50 mm: +12.5 / −12.5 µm. js7: 10–18 mm: +9 / −9 µm; 18–30 mm: +10.5 / −10.5 µm; 30–50 mm: +12.5 / −12.5 µm. The value grows with size; other bands are in the table.

What are the limits of Ø20 JS7?

JS7: 19.990 – 20.011 mm (+10.5 / −10.5 µm); js7: 19.990 – 20.011 mm (+10.5 / −10.5 µm).

What is the difference between JS7 and js7?

Capitals are hole tolerances, lower case shaft tolerances. At Ø25 mm JS7 is +10.5 / −10.5 µm and js7 +10.5 / −10.5 µm: the same width (IT7) in a different position.

Where is JS7 used?

JS7 and js7 are symmetric tolerances: the deviation is split evenly on both sides of the nominal size (± IT7 / 2). Used for location dimensions that should sit centrally and in transition fits.

What does IT7 mean?

IT7 is the ISO 286 tolerance grade and sets the width of the tolerance; it grows with size. At Ø25 mm IT7 = 21 µm. IT7 is usually reached by reaming, precision turning or grinding.

How do I calculate a JS7 tolerance?

Find the band containing the nominal size and add the upper / lower deviation (µm) to it. Example: Ø20 JS7: 20 +10.5 µm = 20.011 mm and 20 −10.5 µm = 19.990 mm. The calculator does this for you.