PRECISION IN MATERIAL. CLARITY IN SUPPLY.

ISO 286 TOLERANCES

m6 tolerance chart

ISO 286 values for the m6 shaft tolerance. Enter a diameter to see the limits; a table for every size band follows below.

Dimension and tolerance

Standard

Feature type

Tolerance class
ISO m6
Quick entry by tolerance notation

Examples: 20 h9 · 25 H7/g6

Verified table coverage: 0 < size ≤ 3150 mm; class-specific limits apply. Lists change with dimension. A selected class is not a delivery tolerance commitment.

TOLERANCE CALCULATION

Size limits

25 m6 m6: 25.008 – 25.021 mm (+8 / +21 µm)

Diameter

m6
Minimum size
25.008 mm
Maximum size
25.021 mm
Lower deviation
+8 µm (+0.008 mm)
Upper deviation
+21 µm (+0.021 mm)
Tolerance width
13 µm (0.013 mm)
Check a measured size

This check compares numerical size limits only; it does not assess measurement uncertainty or form tolerances.

Tolerance zone µm
Nominal · 0m6821

Calculate weight from nominal dimensions

The result shows size limits for the selected ISO class. Ovality, straightness, surface roughness and temperature effects are outside this calculation.

m6 tolerance chart

Values from ISO 286-2 for every size band up to 3150 mm, in micrometres (µm). Add the deviations to the nominal size; the calculator above gives the limits in millimetres.

m6 tolerance chartupper / lower deviation, µm · IT: tolerance width, µm
Size (mm)m6 shaftIT6
0–3+8 / +26
3–6+12 / +48
6–10+15 / +69
10–18+18 / +711
18–30+21 / +813
30–50+25 / +916
50–80+30 / +1119
80–120+35 / +1322
120–180+40 / +1525
180–250+46 / +1729
250–315+52 / +2032
315–400+57 / +2136
400–500+63 / +2340
500–630+70 / +2644
630–800+80 / +3050
800–1000+90 / +3456
1000–1250+106 / +4066
1250–1600+126 / +4878
1600–2000+150 / +5892
2000–2500+178 / +68110
2500–3150+211 / +76135

Worked examples

  1. Ø10 m6 shaft: in the 6–10 mm band m6 is +15 / +6 µm, so the size must lie between 10.006 and 10.015 mm.
  2. Ø25 m6 shaft: in the 18–30 mm band m6 is +21 / +8 µm, so the size must lie between 25.008 and 25.021 mm.
  3. Ø50 m6 shaft: in the 30–50 mm band m6 is +25 / +9 µm, so the size must lie between 50.009 and 50.025 mm.

What does m6 mean?

In an ISO 286 code the letter gives the position of the tolerance zone relative to the nominal size and the number its width (grade IT6). Capital letters are for holes, lower case for shafts.

Both deviations of m6 are positive: the shaft is always slightly above the nominal size, which is why it gives a transition or interference fit with an H hole.

IT6 is usually reached by grinding or precision turning.

Where is m6 used?

m6 sits on the tighter side of transition fits (H7/m6). Hardened dowel pins to ISO 8734 are made to m6.

How to read the m6 tolerance chart

First find the row containing the nominal size: “10–18” covers sizes above 10 mm up to and including 18 mm. Add the upper and lower deviations of that row, in micrometres, to the nominal size; 1000 µm = 1 mm.

The tolerance width is the difference between the upper and lower deviation and equals IT6. Classes ending in the same number (for example H6, h6, js6) share this width; the letter only moves the zone.

Frequently asked questions

What is the m6 tolerance value?

m6: 10–18 mm: +18 / +7 µm; 18–30 mm: +21 / +8 µm; 30–50 mm: +25 / +9 µm. The value grows with size; other bands are in the table.

What are the limits of Ø20 m6?

m6: 20.008 – 20.021 mm (+21 / +8 µm).

Where is m6 used?

m6 sits on the tighter side of transition fits (H7/m6). Hardened dowel pins to ISO 8734 are made to m6.

What does IT6 mean?

IT6 is the ISO 286 tolerance grade and sets the width of the tolerance; it grows with size. At Ø25 mm IT6 = 13 µm. IT6 is usually reached by grinding or precision turning.

How do I calculate a m6 tolerance?

Find the band containing the nominal size and add the upper / lower deviation (µm) to it. Example: Ø20 m6: 20 +21 µm = 20.021 mm and 20 +8 µm = 20.008 mm. The calculator does this for you.