ISO 286 TOLERANCES
k6 tolerance chart
ISO 286 values for the k6 shaft tolerance. Enter a diameter to see the limits; a table for every size band follows below.
Dimension and tolerance
Standard
Feature type
Quick entry by tolerance notation
Examples: 20 h9 · 25 H7/g6
Verified table coverage: 0 < size ≤ 3150 mm; class-specific limits apply. Lists change with dimension. A selected class is not a delivery tolerance commitment.
TOLERANCE CALCULATION
Size limits
Diameter
k6- Minimum size
- 25.002 mm
- Maximum size
- 25.015 mm
- Lower deviation
- +2 µm (+0.002 mm)
- Upper deviation
- +15 µm (+0.015 mm)
- Tolerance width
- 13 µm (0.013 mm)
Check a measured size
This check compares numerical size limits only; it does not assess measurement uncertainty or form tolerances.
The result shows size limits for the selected ISO class. Ovality, straightness, surface roughness and temperature effects are outside this calculation.
k6 tolerance chart
Values from ISO 286-2 for every size band up to 3150 mm, in micrometres (µm). Add the deviations to the nominal size; the calculator above gives the limits in millimetres.
k6 tolerance chartupper / lower deviation, µm · IT: tolerance width, µm
| Size (mm) | k6 shaft | IT6 |
|---|---|---|
| 0–3 | +6 / 0 | 6 |
| 3–6 | +9 / +1 | 8 |
| 6–10 | +10 / +1 | 9 |
| 10–18 | +12 / +1 | 11 |
| 18–30 | +15 / +2 | 13 |
| 30–50 | +18 / +2 | 16 |
| 50–80 | +21 / +2 | 19 |
| 80–120 | +25 / +3 | 22 |
| 120–180 | +28 / +3 | 25 |
| 180–250 | +33 / +4 | 29 |
| 250–315 | +36 / +4 | 32 |
| 315–400 | +40 / +4 | 36 |
| 400–500 | +45 / +5 | 40 |
| 500–630 | +44 / 0 | 44 |
| 630–800 | +50 / 0 | 50 |
| 800–1000 | +56 / 0 | 56 |
| 1000–1250 | +66 / 0 | 66 |
| 1250–1600 | +78 / 0 | 78 |
| 1600–2000 | +92 / 0 | 92 |
| 2000–2500 | +110 / 0 | 110 |
| 2500–3150 | +135 / 0 | 135 |
Worked examples
- Ø10 k6 shaft: in the 6–10 mm band k6 is +10 / +1 µm, so the size must lie between 10.001 and 10.010 mm.
- Ø25 k6 shaft: in the 18–30 mm band k6 is +15 / +2 µm, so the size must lie between 25.002 and 25.015 mm.
- Ø50 k6 shaft: in the 30–50 mm band k6 is +18 / +2 µm, so the size must lie between 50.002 and 50.018 mm.
What does k6 mean?
In an ISO 286 code the letter gives the position of the tolerance zone relative to the nominal size and the number its width (grade IT6). Capital letters are for holes, lower case for shafts.
Both deviations of k6 are positive: the shaft is always slightly above the nominal size, which is why it gives a transition or interference fit with an H hole.
IT6 is usually reached by grinding or precision turning.
Where is k6 used?
k6 is the shaft tolerance giving the H7/k6 transition fit: for parts fitted with light pressure that must keep their location, and common on shaft seats for rolling bearings with rotating inner rings.
How to read the k6 tolerance chart
First find the row containing the nominal size: “10–18” covers sizes above 10 mm up to and including 18 mm. Add the upper and lower deviations of that row, in micrometres, to the nominal size; 1000 µm = 1 mm.
The tolerance width is the difference between the upper and lower deviation and equals IT6. Classes ending in the same number (for example H6, h6, js6) share this width; the letter only moves the zone.
Frequently asked questions
What is the k6 tolerance value?
k6: 10–18 mm: +12 / +1 µm; 18–30 mm: +15 / +2 µm; 30–50 mm: +18 / +2 µm. The value grows with size; other bands are in the table.
What are the limits of Ø20 k6?
k6: 20.002 – 20.015 mm (+15 / +2 µm).
Where is k6 used?
k6 is the shaft tolerance giving the H7/k6 transition fit: for parts fitted with light pressure that must keep their location, and common on shaft seats for rolling bearings with rotating inner rings.
What does IT6 mean?
IT6 is the ISO 286 tolerance grade and sets the width of the tolerance; it grows with size. At Ø25 mm IT6 = 13 µm. IT6 is usually reached by grinding or precision turning.
How do I calculate a k6 tolerance?
Find the band containing the nominal size and add the upper / lower deviation (µm) to it. Example: Ø20 k6: 20 +15 µm = 20.015 mm and 20 +2 µm = 20.002 mm. The calculator does this for you.