PRECISION IN MATERIAL. CLARITY IN SUPPLY.

PRODUCT TOLERANCES

Box section tolerances

Enter the section size and wall to see the EN 10219-2 limits on outside dimensions and wall, and the corner radius range.

Dimension and tolerance

Standard

Cold-formed welded square and rectangular hollow sections (EN 10219-2:2019). The outside dimension tolerance is 1 %, 0.8 % or 0.6 % depending on side length.

PRODUCT TOLERANCE

Size limits

Height (H)

EN 10219-2
Minimum size
39.5 mm
Maximum size
40.5 mm
Lower deviation
−0.5 mm
Upper deviation
+0.5 mm
Tolerance width
1 mm

Wall thickness

± 10 %
Minimum size
1.8 mm
Maximum size
2.2 mm
Lower deviation
−0.2 mm
Upper deviation
+0.2 mm
Tolerance width
0.4 mm
External corner profile
3.2 – 4.8 mm
Squareness
90° ± 1°
Twist
2 mm + 0.5 mm/m
Straightness
0.15 % of length
EN 10219-2 Height (H) (EN 10219-2): 39.5 – 40.5 mm (−0.5 / +0.5 mm) Wall thickness (± 10 %): 1.8 – 2.2 mm (−0.2 / +0.2 mm) External corner profile: 3.2 – 4.8 mm Squareness: 90° ± 1° Twist: 2 mm + 0.5 mm/m Straightness: 0.15 % of length

The result shows size limits only; form tolerances not listed, flatness and surface condition are not covered. Use the current edition of the standard for orders.

Box section tolerances

EN 10219-2:2019 tolerances for cold-formed welded square and rectangular hollow sections.

EN 10219-2 tolerances, square and rectangular sectionsTolerance
CharacteristicTolerance
Outside dimension, H, B < 100 mm± 1 %, at least ± 0.5 mm
Outside dimension, 100–200 mm± 0.8 %
Outside dimension, > 200 mm± 0.6 %
Wall, T ≤ 5 mm± 10 %
Wall, T > 5 mm± 0.5 mm
Concavity / convexitymax. 0.8 %, at least 0.5 mm
Squareness of sides90° ± 1°
Twist2 mm + 0.5 mm/m
Straightness0.15 % of length, 3 mm over any 1 m
Mass per length± 6 % per length
EN 10219-2 external corner profileCorner (C or R)
Wall thickness TCorner (C or R)
T ≤ 61.6T – 2.4T
6 < T ≤ 102.0T – 3.0T
T > 102.4T – 3.6T

Worked examples

  1. 40 × 40 × 2 mm box section: 1 % is 0.4 mm, so the ±0.5 mm minimum applies → 39.5–40.5 mm. Wall ±10 % → 1.8–2.2 mm. Corner 3.2–4.8 mm.
  2. 150 × 150 × 8 mm: outside ±0.8 % = ±1.2 mm; walls over 5 mm are ±0.5 mm; corner 16–24 mm.

EN 10219-2 box section tolerances

EN 10219-2 gives size and shape tolerances for cold-formed welded structural hollow sections. For square and rectangular sections the outside tolerance depends on side length: ±1 % below 100 mm (at least ±0.5 mm), ±0.8 % for 100–200 mm and ±0.6 % above 200 mm.

Wall thickness is ±10 % up to 5 mm and ±0.5 mm above. Squareness is 90° ±1°, twist 2 mm + 0.5 mm/m, straightness 0.15 % of the total length and 3 mm over any 1 m, and mass ±6 % on each length.

Box section corner radius

The external corner profile is a range that depends on the wall: 1.6T–2.4T for T ≤ 6 mm, 2.0T–3.0T for 6–10 mm and 2.4T–3.6T above 10 mm. The calculation radii used for weight (2T, 2.5T, 3T) sit in the middle of these ranges.

Frequently asked questions

What are the box section tolerances?

To EN 10219-2 the outside dimension is ±1 % below 100 mm (at least ±0.5 mm), ±0.8 % for 100–200 mm and ±0.6 % above; the wall is ±10 % up to 5 mm and ±0.5 mm above.

What is the box section wall thickness tolerance?

±10 % up to 5 mm and ±0.5 mm for thicker walls. A 40 × 40 × 2 section has a 1.8–2.2 mm wall, 100 × 100 × 4 3.6–4.4 mm.

What is the corner radius of a box section?

It depends on the wall: up to 6 mm it is 1.6T–2.4T. For a 2 mm wall the external corner is 3.2–4.8 mm.

What are the squareness and twist tolerances?

Squareness is 90° ±1°; twist 2 mm plus 0.5 mm per metre. Straightness is 0.15 % of the total length and 3 mm over any 1 m.

Can box section weight deviate?

EN 10219-2 allows ±6 % on the mass of each delivered length. Wall thickness and corner radius are the main reasons for the difference.