TOLERANCE ANALYSIS
Tolerance stack-up calculator: worst case and RSS
Enter the parts’ dimensions, tolerances and whether each one widens or closes the gap to see the range of the assembly gap in the worst case and statistically. Tolerances can also be ISO 286 classes (h9, H7).
Dimension chain
“+” dimensions widen the gap and “−” dimensions close it; tap the button to switch. For a symmetric tolerance just type the number (0.05 = ±0.05); use “+0.2/−0.1” for unequal deviations or an ISO 286 class such as h9, H7, g6.
WORST CASE AND RSS
Closing dimension (gap)
- Worst case (min … max)
- −0.050 … 0.450 mm
- Worst-case tolerance
- ± 0.250 mm
- Statistical (RSS)
- 0.200 ± 0.132 mm
- RSS (min … max)
- 0.068 … 0.332 mm
In the worst case the gap goes negative: the parts can interfere.
Contribution (worst case)
What is a tolerance stack-up?
In an assembly, part dimensions add up and leave a closing dimension between them: a gap, an interference or the position of a face. Every dimension’s tolerance carries over into that closing dimension; this is the tolerance stack-up. Parts that are each made within tolerance can still bind or leave too much play when their deviations add in the same direction. A tolerance analysis shows this before production.
How to do a tolerance stack-up analysis
1) Choose the closing dimension to study (e.g. a gap). 2) Draw the loop of dimensions from that gap through the parts and back. 3) Mark dimensions that widen the gap “+” and those that close it “−”. 4) The nominal gap is the signed sum. 5) Calculate the range with worst case and RSS and compare it with the required gap.
Example: three parts of 20, 15 and 14.8 mm (each ± 0.05) stack inside a 50 ± 0.1 mm housing. The nominal gap is 50 − 20 − 15 − 14.8 = 0.2 mm. In the worst case it ranges from −0.05 to 0.45 mm; the negative value means the parts can bind. With RSS the range is 0.068 … 0.332 mm.
Worst-case method
In the worst case every dimension sits at the limit that widens or closes the gap most. The largest gap uses the upper limits of “+” dimensions and the lower limits of “−” dimensions; the smallest gap the opposite. The closing tolerance is the sum of the individual tolerances. The method is safe and suits short chains and safety-critical assemblies, but it demands unnecessarily tight tolerances as the number of parts grows.
Statistical (RSS) method
In the RSS (root sum square) method the closing tolerance is T = √(t₁² + t₂² + … + tₙ²), where tᵢ is each dimension’s half tolerance range. If the dimensions are independent, normally distributed and centred, and each tolerance is ± 3σ, about 99.73 % of assemblies fall inside this range. Because all parts rarely sit at their worst limits together, RSS allows wider part tolerances; it is used in series production and for long chains.
For asymmetric tolerances (e.g. 30 +0.021/0), RSS works from the middle of each tolerance zone, so the mean RSS gap can differ from the nominal gap.
Stack-ups with ISO 286 classes
If tolerances are given as ISO 286 classes, just enter the class (H7, g6, h9); the deviations are looked up for the nominal size. For example, a Ø30 H7 hole is +0.021/0 mm and a Ø30 g6 shaft −0.007/−0.02 mm. For a simple hole–shaft fit you can also use the fit mode of the tolerance calculator.
Frequently asked questions
What is tolerance analysis?
It calculates how part tolerances combine in an assembly gap or dimension. Worst case and statistical (RSS) are the two most common methods.
What is the difference between worst case and RSS?
Worst case adds the tolerances and assumes every part is at its limit at once. RSS takes the square root of the sum of squares, assumes independent, centred production and gives a narrower range.
What is the RSS tolerance formula?
T = √(t₁² + t₂² + … + tₙ²), with tᵢ each dimension’s half tolerance range; the mean uses the middle of each tolerance zone.
Tolerance stack-up example
Parts of 20, 15 and 14.8 mm (± 0.05) in a 50 ± 0.1 housing: nominal gap 0.2 mm, worst case −0.05 … 0.45 mm, RSS 0.068 … 0.332 mm.
Which method should I use?
Use worst case for short chains, safety-critical assemblies and one-off work; use RSS for long chains and controlled series production. RSS accepts that a small share of assemblies may fall outside the range.
Do I need a spreadsheet for a stack-up?
No. The calculator runs in the browser with up to 20 dimensions, gives worst case and RSS together, and the result can be shared as a link.